Plate 9:  Ballast tank flooding and venting system

     

   
PLATE 9 - TAUCHZELLENFLUT- und ENTLÜFTUNGSANLAGE
Ballast tank flooding and venting system
     
 
  a FLUTKLAPPE. . . zB TAUCHBUNKER 2 STEUERBORD  3 STEUERBORD
    Flood (flap) valve. . . for example, main ballast and reserve fuel oil tank 3 starboard
     
  b ENTLÜFTUNGSVENTIL. . . zB TAUCHBUNKER 2 und 3  3 und 4
    Vent valve. . . for example, main ballast and reserve fuel oil tanks 3 and 4
     
  c NOTVERSCHLUẞKLAPPE. . . zB TAUCHBUNKER   2    3
    Emergency vent (flap) valve. . . for example, main ballast and reserve fuel oil tank 3
     
  c1 NOTVERSCHLUẞKLAPPE RESTENTLÜFTUNG    TAUCHBUNKER 7 STEUERBORD und BACKBORD
    Emergency vent valve, residual vent line   main ballast and reserve fuel oil tanks 7, port and starboard
     
  d ENTLÜFTUNGSANSCHLUẞ. . . zB TAUCHBUNKER    2    3
    Vent valve. . . for example, main ballast and reserve fuel oil tank 3
     
  e DRUCKAUSGLEICH und ENTWÄSSERN ENTLÜFTUNGSLEITUNG. . . zB TAUCHBUNKER 2 STEUERBORD  7 STEUERBORD
    Equalization and drainage vent valve. . . for example, main ballast and reserve fuel oil tank 7 starboard
     
  f      ENTWÄSSERN ENTLÜFTUNGSLEITUNG bei FROSTGEFAHR TAUCHBUNKER 4 STEUERBORD bzw BACKBORD
  Drainage vent line in case of frost danger. . . for example, main ballast and reserve fuel oil tank 4 starboard and port
     
    f FETTEN. . .  zB FLUTKLAPPE TAUCHBUNKER 2 STEUERBORD 3 STEUERBORD
    Greasing. . .  for example flood (flap) valve main ballast and reserve fuel oil tank 3 starboard
 
     
  [Note: this key is consistent with IXC/39 only.  The plate below is for an IXC/40.  Item f was removed in the IXC/40 and main ballast and reserve fuel oil tank 2 became fuel oil bunker 1a).  To make the key match the lettering in the plate below examples referring to main ballast and reserve fuel oil tank 2 were changed to other tanks, item f was struck through and g was renumbered f.]