Plate 17: Pumping diagram "Suction"

     

   
PLATE 17 - PUMPENPLAN "SAUGEN"
Pumping diagram "Suction"
     
  Translation of the first 5 columns of the table:   Translation of the key at the right of the table      
 
Ser.
Designation
Units for
Type of
Performance of
 
No.
of the pumps
1 Ship
Pump
the pump m³/hour
  1 Main drain pump (P)
1
Centrifugal
parallel: 120
         
series:  40
  2 Auxiliary drain and trim P
1
Piston
110V:   18
         
170V: 215
  3 Auxiliary drain P 1
1
Centrifugal
15
  4 Auxiliary drain P 2
1
Centrifugal
15
  5 Portable hand emergency drain P
1
Hand piston
~8.3
  6 Hand drain P (for periscope shaft)
1
Vane
1.2
  7 Cooling water P stb. & port
2
Piston
92.5
  8 Cooling E-motor room P
1
Centrifugal
   110V: 20
         
   170V: 31.5
  9 Spare cooling water P
1
Centrifugal
   110V: 70-75
         
   170V: 130
  10 Cooling water P
 
        Compressor 1
1
Centrifugal
---
        Compressor 2
1
Vane
---
  11 Hand cooling water P
1
Hand piston
~6.24
  12 Hand emergency drinking water P 1
1
Vane
1.8
  13 Hand emergency drinking water P 2
1
Vane
1.8
  14 Lubricating oil P stb. & port
2
Geared
59
  15 Spare lubricating oil P
1
Axial flow
110V: 48
         
170V: 55
  16 Hand lub. oil P
1
Hand piston
~4.2
  17 Hand dirty lubricating oil P
1
Vane
2.8
  18 Dirty lub. oil P
1
Geared
0.5
  19 Fuel oil forwarding P
2
Geared
2.0
  20 Hand drinking water P
1
Hand piston
~2.88
  21 Hand distillate P fresh water gen.
1
Vane
1.2
22 Hand brine P fresh water generator
1
Hand piston
1.6
  23 Main and auxiliary hydraulic oil P
2
Axial flow
4.5
  24 Circulation P heating steam gen.
1
Centrifugal
12
  25 Feed P heating steam gen.
1
Centrifugal
0.3
  26 Hand filling P heating steam gen.
1
Vane
2.0
  27 Clean lubricating oil P
1
Geared
0.5
  28 Lub. oil turbocharger P stb. & port
2
    ---
---
  29 Cooling P gyro-compass
1
    ---
---
   
   
   
Lichtweite am Rohreintritt
Inner diameter at the entrance of the pipe [in mm]
 
Lichtweite vor der Pumpe
Inner diameter just before the pump [in mm]
   
  Es beduetet ferner
  The following means:
   
Pumpe saugt durch feste Leitung
  Pump sucks through a fixed line
   
Pumpe saugt durch feste Leitung und über Schlauchverbindung
  Pump sucks through a fixed line and a hose connection
   
Pumpe saugt über Schlauchverbindung
  Pump sucks through a hose connection
   
 
   
   
   
   
Fällt ab Werk Nr. 1035 fort
  Discontinued from Work No. 1035 onwards
 
     
 
Insert in the center at the bottom of the table
  Hand wash water P 1
1
Vane
1.2
Sucks from torpedo compensating tank 1 & 2
  Hand wash water P 2
1
Vane
1.2
Sucks from torpedo compensating tank 3 & 4
  Hand wash water P 3
1
Vane
2.4
Sucks from sea or cooling water header tank